5
B

10.811
No spectrum
currently
available
No photo
currently
available

Web Elements
NIST Online
Plasus SpecLine trial version
Download spectral data
View experimental conditions

References ordered by physical form of material analysed
GO TO:
Solids analysis references
No surface analysis references
Liquids analysis references
No gases/aerosols analysis references

PHYSICAL
FORM OF
MATERIAL
LOD /
RSD
MATRIX
COMMENTS
REFERENCE
ANALYTE /
MATRIX LINES
λ (nm)
Solid
1.5 ppm, 0.3 ppm /
RSD not reported (error 5 – 10%)
Wood
Single-shot and 20-shot measurements. Nd:YAG laser (1064 nm), Echelle spectrometer & ICCD camera. Al, As, B, Cd, Cr, Cu, Hg, K, Mg, Na, Pb, Si, Sn.
A. Uhl, K. Loebe and L. Kreuchwig Fast analysis of wood preservers using laser
Induced breakdown Spectroscopy. Spectrochim. Acta Part B,  56, (2001), 795-806.
249.773 /
C (247.857)
Solid
65 ppm /
10%
UO2 
Nuclear fuel pellets. Nd:YAG laser (532 nm). Ag, Al, B, Ba, Bi, Cr, Cu, Fe, Ga, In, Li, Mg, Mn, Pb, Sr, Tl.
(Ca, Cd, Co, Na, Zn – LOD not determined)
P. Fichet, P. Mauchien and C. Moulin. Determination of impurities in uranium and plutonium dioxides by laser-induced breakdown spectroscopy. Appl. Spectrosc., 53, (1999), 1111-1117.
249.7733 /
not applicable
Solid
30 ppm,
40 ppm /
RSD not reported
Glass
Air atmosphere at 1 and 5 Torr. TEA-CO2 laser (10.6 µm) & XeCl excimer laser (308 nm). Li, B, Na, Mg, Al, K, Ca, Ti, Zn, Zr, Ba.
H. Kurniawan, S. Nakajima, J.E. Batubara, M. Marpaung, M. Okamoto and K. Kagawa.
Laser-induced wave plasma in glass and its application to elemental analysis. Appl. Spectrosc., 49, (1995), 1067-1072.
345.1 /
not applicable
Liquid
0.054 ppm (estimated) /
RSD not reported
Electro- deposited metals on nickel electrode
TEA CO2 laser, vacuum sample chamber, monochromator and PMT detector.  Metals electro-deposited on nickel plate electrode from aqueous solutions. B, Cu, Fe, Li, Pb.
M. Pardede, H. Kurniawan, M.O. Tjja, K. Ikezawa, T. Maruyama and K. Kagawa. Spectrochemical analysis of metal elements electrodeposited from water samples by laser-induced shock wave plasma spectroscopy. Appl. Spectrosc., 55, (2001), 1229-1236.
249.7 /
not applicable
Liquid
80 ppm /
4 – 8%
Water,
Organic solvents
RSP (double pulse). Plasma formed within the liquid. Nd:YAG laser (1064 nm). Li, Na, K, Rb, Cs, Be, Mg, Ca, B, Al. PMT detector.
D.A. Cremers, L.J. Radziemski and T.R. Loree. Spectrochemical analysis of liquids using the laser spark. Appl. Spectrosc,. 38, (1984), 721-729.
 
249.68 & 249.77 /
not applicable
Liquid
1200 ppm /
4 – 8%
Water,
Organic solvents
RSS (single pulse). Plasma formed within the liquid. Nd:YAG laser (1064 nm). Li, Na, K, Rb, Cs, Be, Mg, Ca, B, Al. PMT detector.
D.A. Cremers, L.J. Radziemski and T.R. Loree. Spectrochemical analysis of liquids using the laser spark. Appl. Spectrosc,. 38, (1984), 721-729.
249.68 & 249.77 /
not applicable